construction Contact Service email General Contact public Contact Sales travel_explore Contact Partner
construction email public travel_explore
Product filter
Product Filter
Newsearch
Environmental dust monitor EDM 280

EDM 280
Environmental dust monitor for PM monitoring in ambient air

Latest generation optical aerosol spectrometer with unique detection limit and excellent counting efficiency. Suitable for real-time PM monitoring under any environmental conditions and at all sites.


Functionality: Light scattering at single particles

  • Latest generation 19‑inch based optical aerosol spectrometer, unique detection limit and excellent counting efficiency
  • TÜV approved according to DIN EN 16450
  • Honored at the Reiner-Lemoine-Innovation-Award 2023
  • Touch display for intuitive menu control with colorguided status information
  • All-weather sampling system, –40 to 60 °C, 60 g/m³ absolute humidity and wind
  • Output of six dust mass fractions TSP, PM10, PM4, PM2.5, PM1, PMcoarse, total particle concentration and particle number size distribution
  • Aerodynamic aerosol focusing as per ISO 21501‑1, no border zone error, total inlet flow analyzed in optical cell
  • PSL traceable particle sizing as per ISO 21501‑1 
  • Flexible data protocols: GRIMM protocol, Modbus, GESYTEC / Bayern-Hessen protocol
  • Suitable for PM monitoring under any environmental conditions and at all sites (traffic, urban, background, maritime, mountain and others)
  • Robust design, energy efficient and lowest running costs
  • Low maintenance due to internal particle-free purge-air circuit to protect the optical components
  • Fits in all existing EDM (180, 180+) installations
  • Stand-alone option with fully air-conditioned weather protection housing (construction site monitoring, port facilities, etc.)
  • Approved immission measuring device for particulate matter PM10 and PM2.5 in air monitoring networks
  • Source apportionment with high time resolution for air pollution control strategies
  • Insensitive to vibrations, therefore also suitable for installation in measuring vehicles
  • Technical data
Detection principleLight scattering at single particles with diode laser; detection volume aerodynamically focused (ISO 21501‑1), no border zone error
Measured mass fractionsTSP, PM10, PM4, PM2.5, PM1, PMcoarse
Particle size range0.178 μm < Do < 29.4 μm (Do = optical latex equivalent diameter)
Size channels72, channel boundaries equidistant, 32 channels per decade
Mass concentration0 … 12,000 μg/m³ for PM100 … 5,100 μg/m³ for PM2.5 (with 10 % coincidence error for Arizona Dust A1 ultrafine)
Detection limit0.1 μg/m³ for PM10
Zero level≤ 0.1 μg/m³
Sample volume flow1.2 l/min, accuracy ≤ 2 %, constant at the orifice plate by regulation
Internal purge air0.3 to 0.5 l/min, protection of laser optics, reference air for self-test
Storage intervalSelectable, 6 seconds, 1, 5, 10, 15, 30, 60 minutes, daily average value
Data interfacesRS-232 (selectable up to 115,200 baud/s), USB-B, Ethernet, USB flash drive (USB 2.0), data logger
Data protocol (ASCII)GRIMM protocol, Modbus TCP, GESYTEC / Bayern / Hessen Protocol
Meteo sensorTemperature: –50 … 60 °C, ±0.2 °C (–20 … 50 °C), otherwise ±0.5 °C (> –30 °C)Relative humidity: 0 … 100 % RH, ±2 % RHAir pressure: 300 … 1,200 hPa, ±0.5 hPa (0 … 40 °C)
OperationVia touch display or PC via data interface
Power supplyWide range power supply 100 … 240 VAC at 50 … 60 Hz, 4 A
Power consumptionTypical 25 W (continental warm)Typical 40 W (tropical humid)Typical 80 W (polar cold)Typical 220 W (maximum equipment, all heaters at maximum power)
Conditions (sample air on site)Temperature: –40 … 60 °CRelative humidity: 100 % (–40 °C) … 30 % (60 °C) or maximum 60 g/m³ absolute humidityAmbient pressure: 530 … 1,080 hPa
Conditions (measuring container)Temperature: 5 … 40 °CRelative humidity: 5 … 90 %, non-condensing
Transport and storage–20 … +50 °C, RH < 95 % (non-condensing)
Dimensions (H x W x D)19″ spectrometer: 180.5 x 434 x 320 mmSample tube holder: 88.9 x 441 x 156 mmSample tube with sampling head: 1500 (L) x Ø 45 (tube) / Ø 105 mm (Sigma-2 sample inlet)
WeightTotal: 20.5 kg (with meteo sensor 157L, 2.35 kg)19″ spectrometer: 10.45 kgSample tube holder: 2.4 kgSample tube with sampling head: 5.3 kg
  • Optional
199: Stand-alone, fully air-conditioned weather protection housing, providing space for EDM 180+ and other 19″ rack instruments